Our Vfix™ consists of a 6-layer anti-corrosion coating structure made up of reflective foil, film, and reinforced non-woven bonded to high-adhesive butyl.

Heavy duty |
Prolonged exposure to harsh weather conditions |
Easy cleaning |
Waterproofing and solving the leaking issue |
High solar reflectance and excellent thermal performance |
Sound-dampening effect and noise reduction |
Anti corrosion |

Anti Corrosion Coating
Reflective Foil
Film
Reinforced Non-Woven
Butyl Adhesive
Release Film
Roof Cleaning
Surface Undercoating
ACC Weathering Membrane Installation
Intersection Sealing
Characteristic |
Test Method |
Unit (SI) |
Specification |
|---|---|---|---|
Grammage |
ISO 536 |
g/m² |
159 ± 10% |
Thickness |
In-house |
μ |
240 ± 10% |
Solar Reflectance |
ASTM C1549 |
– |
≥ 0.80 |
Tensile Strength Before Ageing MD CD |
ISO 9073-3 |
N/50mm |
≥ 325 ≥ 300 |
Tensile Strength After Ageing MD CD |
ISO 9073-3 |
N/50mm |
≥ 80% before ageing ≥ 80% before ageing |
Tear Resistance |
ISO 9073-4 |
N |
≥ 25 ≥ 35 |
Nail Shank |
BS EN 12310-1 |
N |
≥ 45 ≥ 50 |
Ageing (70°C, 90% RH for 28 Days) |
ISO 22097 |
– |
No Corrosion |
Acid rain corrosion test (pH 3.15) |
ASTM D7356 |
– |
No Corrosion |
Accelerated Weathering (QUV) – UV Exposure: 8.00hr, 80°C – Water Spray: 0.25hr – Condensation: 3.75hr, 50°C For duration of 5000 hours |
ASTM G154 |
– |
No Corrosion No Chalking No Delamination |
Box Gutter and
Sheet Metal Roof Application
Sheet Metal Roof: Various Profiles | Flat Concrete Roof | Solar | Parapet Walls
Sheet Metal Roof:
Solar PV Specific










One-pack multi-surface primer suitable for aluminium, galvanising, fibreglass, stainless steel, mild steel, wood, and previously painted surfaces.

Degrease all surfaces and allow to dry
Lightly sand if required
Wipe down and remove all dust with a clean, damp cloth
Apply ACC Multi-Surface Primer and leave to cure before applying ACC Weathering Membrane (± 12h)